De Rooij, M., Van der Plicht, J. and Meijer, H. (2008). Sample dilution for AMS ¹â´C analysis of small samples (30'“150 μg C) . Radiocarbon 50 (3). Vol 50(3), pp. 413-436.
Title The title of the publication or report |
Sample dilution for AMS ¹â´C analysis of small samples (30'“150 μg C) | ||
---|---|---|---|
Issue The name of the volume or issue |
Radiocarbon 50 (3) | ||
Series The series the publication or report is included in |
Radiocarbon | ||
Volume Volume number and part |
50 (3) | ||
Number of Pages The number of pages in the publication or report |
185 | ||
Page Start/End The start and end page numbers. |
413 - 436 | ||
Biblio Note This is a Bibliographic record only. |
The ADS have no files for download on this page but further information is available online, normally as an electronic version maintained by the Publisher, or held in a larger collection such as an ADS Archive. Please refer to the DOI or URI listed in the Relations section of this record to locate the information you require. In the case of non-ADS resources, please be aware that we cannot advise further on availability. | ||
Publication Type The type of publication - report, monograph, journal article or chapter from a book |
Journal | ||
Abstract The abstract describing the content of the publication or report |
By diluting samples up to a total weight of 200 μg, reliable AMS measurements can still be performed, and the success rate for targets that are difficult to measure can be significantly improved. A disadvantage of this dilution technique is a loss of measurement precision. In addition, calculations of the ¹â´C/¹²C isotope ratios and the uncertainties therein are not straightforward because of peculiarities in isotope fractionation processes in the AMS system. Therefore, to make sample dilution a routine method in our laboratory, extensive theoretical and experimental research to find the optimum conditions for all relevant parameters was carried out. Reports on the first detailed study dealing with all aspects of sample dilution. As an illustrative test case ¹â´C data for CO2 extracted from an ice core, from which samples of 35 μg C or less are available, is analysed. | ||
Year of Publication The year the book, article or report was published |
2008 | ||
Source Where the record has come from or which dataset it was orginally included in. |
BIAB
(biab_online)
|
||
Relations Other resources which are relevant to this publication or report |
|
||
Created Date The date the record of the pubication was first entered |
12 Apr 2010 |