Boudin, M., Boeckx, P., Vandenabeele, P., Mitschke, S. and Strydonck, van, M. J Y. (2011). Monitoring the presence of humic substances in wool and silk by the use of nondestructive fluorescence spectroscopy. Radiocarbon 53 (3). Vol 53(3), pp. 429-442.
Title The title of the publication or report |
Monitoring the presence of humic substances in wool and silk by the use of nondestructive fluorescence spectroscopy | ||
---|---|---|---|
Subtitle The sub title of the publication or report |
quality control for 14C dating of wool and silk | ||
Issue The name of the volume or issue |
Radiocarbon 53 (3) | ||
Series The series the publication or report is included in |
Radiocarbon | ||
Volume Volume number and part |
53 (3) | ||
Number of Pages The number of pages in the publication or report |
139 | ||
Page Start/End The start and end page numbers. |
429 - 442 | ||
Biblio Note This is a Bibliographic record only. |
The ADS have no files for download on this page but further information is available online, normally as an electronic version maintained by the Publisher, or held in a larger collection such as an ADS Archive. Please refer to the DOI or URI listed in the Relations section of this record to locate the information you require. In the case of non-ADS resources, please be aware that we cannot advise further on availability. | ||
Publication Type The type of publication - report, monograph, journal article or chapter from a book |
Journal | ||
Abstract The abstract describing the content of the publication or report |
Radiocarbon dating of degraded wool and silk provides 14C results of questionable reliability. In most cases, degraded wool/silk contains humic substances (HSs). Thus, a nondestructive fluorescence spectroscopy method, using a fiberoptic probe, was developed to monitor the presence of HSs in degraded wool and silk. This method can provide information about the presence of HSs before and after pretreatment and about the 14C age reliability. Suggests considering with care wool/silk samples 14C dating wherein HSs are detected, because the conventional solvent pretreatment method using a NaOH wash is in most cases not sufficient to remove all humic substance contaminants. As a result, unreliable 14C dates can be provided. | ||
Year of Publication The year the book, article or report was published |
2011 | ||
Source Where the record has come from or which dataset it was orginally included in. |
BIAB
(biab_online)
|
||
Relations Other resources which are relevant to this publication or report |
|
||
Created Date The date the record of the pubication was first entered |
23 Feb 2013 |