Walsh, T. (2008). A prefabricated temporary building at Cranford Primary School, Kettering, Northamptonshire. Northamptonshire Archaeology 35. Vol 35, pp. 277-285. https://doi.org/10.5284/1083371. Cite this via datacite

Title
Title
The title of the publication or report
Title:
A prefabricated temporary building at Cranford Primary School, Kettering, Northamptonshire
Issue
Issue
The name of the volume or issue
Issue:
Northamptonshire Archaeology 35
Series
Series
The series the publication or report is included in
Series:
Northamptonshire Archaeology
Volume
Volume
Volume number and part
Volume:
35
Page Start/End
Page Start/End
The start and end page numbers.
Page Start/End:
277 - 285
Downloads
Downloads
Any files associated with the publication or report that can be downloaded from the ADS
Downloads:
NAS_35_2008_277-286_Prefab_School.pdf (1 MB) : Download
Licence Type
Licence Type
ADS, CC-BY 4.0 or CC-BY 4.0 NC.
Licence Type:
Creative Commons Attribution 4.0 International Licence icon
Creative Commons Attribution 4.0
International Licence
DOI
DOI
The DOI (digital object identifier) for the publication or report.
DOI
https://doi.org/10.5284/1083371
Publication Type
Publication Type
The type of publication - report, monograph, journal article or chapter from a book
Publication Type:
Journal
Abstract
Abstract
The abstract describing the content of the publication or report
Abstract:
The implementation of the 1944 Education Act raised the school leaving age from 14 to 15 in 1947. As a result a rapid expansion of space was required to accommodate the additional pupils.  One response was the provision of temporary accommodation in prefabricated buildings, utilising the designs for standard huts issued by the Ministry of Works during World War II. A prefabricated building was erected in the grounds of Cranford school in 1946 but, far from being temporary, this was still in use some six decades later. Once common, these buildings are becoming increasingly scarce, and this example was recorded before demolition. The basic structure remained largely as built although the windows had been replaced and few original internal fixtures or fittings survived. The construction method was as described in the Ministry of Works construction manual, although the dimensions of the building and some use of materials suggest that it was a modified form of a standard type 24
Author
Author
The authors of this publication or report
Author:
Tony Walsh
Year of Publication
Year of Publication
The year the book, article or report was published
Year of Publication:
2008
Locations
Locations
Any locations covered by the publication or report. This is not the place the book or report was published.
Locations:
Place: Kettering
Grid Reference: 492590, 276980 (Easting, Northing)
Locations
Locations
Any locations covered by the publication or report. This is not the place the book or report was published.
Subjects / Periods:
modern (MIDAS) prefabricated building (Monus)
Source
Source
Where the record has come from or which dataset it was orginally included in.
Source:
Source icon
ADS Archive (ADS Archive)
Relations
Relations
Other resources which are relevant to this publication or report
Relations:
Created Date
Created Date
The date the record of the pubication was first entered
Created Date:
03 Nov 2020